Panel | ||
---|---|---|
|
Wiki Markup |
---|
Based on the contents of the .inf file, the following is added to the Windows XP and Windows Server 2003 sysprep.inf files under \[SysprepMassStorage\]: <ac:structured-macro ac:name="panel" ac:schema-version="1" ac:macro-id="2967ff2181d01bf0-1ada7e3e-424a4b70-a9cf936c-d6f3353c16a8496c45cc7b65"><ac:rich-text-body> <p>PCI\VEN_1000&DEV_0622 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0624 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0626 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0628 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0030 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0032 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0050 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0054 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0058 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0056 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0640 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0646 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0062 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0054&SUBSYS_1F041028 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0054&SUBSYS_1F051028 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0054&SUBSYS_1F061028 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0054&SUBSYS_1F071028 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0054&SUBSYS_1F081028 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0054&SUBSYS_1F091028 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0058&SUBSYS_1F0E1028 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0058&SUBSYS_1F0F1028 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"<br/> PCI\VEN_1000&DEV_0058&SUBSYS_1F101028 = "C:\Sysprep\Drivers\Storage\LSI-SAS\symmpi.inf"</p></ac:rich-text-body></ac:structured-macro>If you have hardware using an LSI SAS controller (IBM HS21 blades), the section above can be copied and pasted into your sysprep.inf files: |
Panel |
---|
/usr/local/vcl/tools/Windows_XP/Utilities/Sysprep/sysprep.inf |
Panel |
---|
/usr/local/vcl/tools/Windows_Server_2003/Utilities/Sysprep/sysprep.inf |
...
Panel |
---|
/usr/local/vcl/tools/Windows/Utilities/SPDrvScn/spdrvscn.exe |
To insure that the management node can SSH into your virtual machines without problems, you will need to edit the SSH client config for the root user:
No Format |
---|
vi /root/.ssh/config
|
Add the following lines to the top of the configuration file.
No Format |
---|
Host <vmhost> <vmhost ip>
UserKnownHostsFile /dev/null
StrictHostKeyChecking no
|
Where:
This will insure that new VM hosts will not hang on the known hosts prompts when the management node attempts to connect to them for the first time.
...