Note:that batch writing provides at-least-once semantics and does not guarantee Exactly-Once semantics. However, it can be combined with Doris' primary key table to achieve Exactly-Once.

...


Configuration

...

1.

...

General options

KeyDefault ValueRequiredComment
fenodes--YDoris FE http address, multiple addresses are supported, separated by commas
benodes--NDoris BE http address, multiple addresses are supported, separated by commas. refer to #187
jdbc-url--Njdbc connection information, such as: jdbc:mysql://127.0.0.1:9030
table.identifier--YDoris table name, such as: db.tbl
username--Yusername to access Doris
password--YPassword to access Doris
auto-redirectfalseNWhether to redirect StreamLoad requests. After being turned on, StreamLoad will be written through FE, and BE information will no longer be displayed. At the same time, it can also be written to SelectDB Cloud by turning on this parameter.
doris.request.retries3NNumber of retries to send requests to Doris
doris.request.connect.timeout.ms30000NConnection timeout for sending requests to Doris
doris.request.read.timeout.ms30000NRead timeout for sending requests to Doris

...


2.

...

Source options

KeyDefault ValueRequiredComment
doris.request.query.timeout.s3600NThe timeout time for querying Doris, the default value is 1 hour, -1 means no timeout limit
doris.request.tablet.sizeInteger. MAX_VALUENThe number of Doris Tablets corresponding to a Partition. The smaller this value is set, the more Partitions will be generated. This improves the parallelism on the Flink side, but at the same time puts more pressure on Doris.
doris.batch.size1024NThe maximum number of rows to read data from BE at a time. Increasing this value reduces the number of connections established between Flink and Doris. Thereby reducing the additional time overhead caused by network delay.
doris.exec.mem.limit2147483648NMemory limit for a single query. The default is 2GB, in bytes
doris.deserialize.arrow.asyncFALSENWhether to support asynchronous conversion of Arrow format to RowBatch needed for flink-doris-connector iterations
doris.deserialize.queue.size64NAsynchronous conversion of internal processing queue in Arrow format, effective when doris.deserialize.arrow.async is true
doris.read.field--NRead the list of column names of the Doris table, separated by commas
doris.filter.query--NThe expression to filter the read data, this expression is transparently passed to Doris. Doris uses this expression to complete source-side data filtering. For example age=18.

3.

...

Lookup Join options

KeyDefault ValueRequiredComment
lookup.cache.max-rows-1NThe maximum number of rows in the lookup cache, the default value is -1, and the cache is not enabled
lookup.cache.ttl10sNThe maximum time of lookup cache, the default is 10s
lookup.max-retries1NThe number of retries after a lookup query fails
lookup.jdbc.asyncfalseNWhether to enable asynchronous lookup, the default is false
lookup.jdbc.read.batch.size128NUnder asynchronous lookup, the maximum batch size for each query
lookup.jdbc.read.batch.queue-size256NThe size of the intermediate buffer queue during asynchronous lookup
lookup.jdbc.read.thread-size3NThe number of jdbc threads for lookup in each task

...

4.

...

Sink options

KeyDefault ValueRequiredComment
sink.label-prefix--YThe label prefix used by Stream load import. In the 2pc scenario, global uniqueness is required to ensure Flink's EOS semantics.
sink.properties.*--NImport parameters for Stream Load.
For example: 'sink.properties.column_separator' = ', ' defines column delimiters, 'sink.properties.escape_delimiters' = 'true' special characters as delimiters, '\x01' will be converted to binary 0x01

JSON format import
'sink.properties.format' = 'json' 'sink.properties. read_json_by_line' = 'true'
Detailed parameters refer to here.
sink.enable-deleteTRUENWhether to enable delete. This option requires the Doris table to enable the batch delete function (Doris 0.15+ version is enabled by default), and only supports the Unique model.
sink.enable-2pcTRUENWhether to enable two-phase commit (2pc), the default is true, to ensure Exactly-Once semantics. For two-phase commit, please refer to here.
sink.buffer-size1MBNThe size of the write data cache buffer, in bytes. It is not recommended to modify, the default configuration is enough
sink.buffer-count3NThe number of write data buffers. It is not recommended to modify, the default configuration is enough
sink.max-retries3NMaximum number of retries after Commit failure, default 3
sink.use-cachefalseNIn case of an exception, whether to use the memory cache for recovery. When enabled, the data during the Checkpoint period will be retained in the cache.
sink.enable.batch-modefalseNWhether to use the batch mode to write to Doris. After it is enabled, the writing timing does not depend on Checkpoint. The writing is controlled through the sink.buffer-flush.max-rows/sink.buffer-flush.max-bytes/sink.buffer-flush.interval parameter. Enter the opportunity.
After being turned on at the same time, Exactly-once semantics will not be guaranteed. Uniq model can be used to achieve idempotence.
sink.flush.queue-size2NIn batch mode, the cached column size.
sink.buffer-flush.max-rows50000NIn batch mode, the maximum number of data rows written in a single batch.
sink.buffer-flush.max-bytes10MBNIn batch mode, the maximum number of bytes written in a single batch.
sink.buffer-flush.interval10sNIn batch mode, the interval for asynchronously refreshing the cache
sink.ignore.update-beforetrueNWhether to ignore the update-before event, ignored by default.

...


Sample Code

1.DataStream API

2.FlinkSQL


Datatype Mapping

Doris TypeFlink Type
NULL_TYPENULL
BOOLEANBOOLEAN
TINYINTTINYINT
SMALLINTSMALLINT
INTINT
BIGINTBIGINT
FLOATFLOAT
DOUBLEDOUBLE
DATEDATE
DATETIMETIMESTAMP
DECIMALDECIMAL
CHARSTRING
LARGEINTSTRING
VARCHARSTRING
STRINGSTRING
BitmapUnsupported datatype
HLLUnsupported datatype

...