Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • Be more familiar with the TIA Syntax well known by S7 programmers
  • Add Type Information to support all available TIA types
  • "Type inference" to be not too verbose

Supported types

BytesTIA NameSuitable Java EquivalentSupported S7 PLCs
1 bitBOOLbooleanall
1BYTE
,
byte[8]?all
1CHAR, SINTbyteall
1USINTshortall
2
WORD,
INTshortall
2WORDbyte[16]?all
2UNITintall
4DWORD
,
byte[32]?all
4DINTintall
4UDINTlongall
4REALfloatall
4TIME??
n+2STRING (equals STRING[254]) / STRING[n]Stringall


Syntax

Datablocks

Addressing is different for non-primitive and primitive types.

...

Code Block
P#DB{db-number}.DBX{byte-offset}.{bit-offset}
Note, here, bit offset is not optional but usually always 0

Type identifier Postfix

Primitives

Generally the TIA Syntax is used:

...

Code Block
SINT
USINT
DINT
LREAL
LINT
ULINTtax
Strings

Please see https://support.industry.siemens.com/tf/WW/en/posts/string-data-type/51621?page=0&pageSize=10

...

Code Block
%DB3.DX4.1
%DB3.DX4.1:BOOL
%DB3.DB4:INT
%DB3.DB4:UINT
%DB3.DW4:REAL

Special Data Areas: Markers, Inputs, Outputs

They are always adressed bit-wise and the syntax is similar to TIA.

Code Block
// Marker
%M1.0 // byte 1, bit 0
%I0.5 // byte 0, bit 5
%Q1.1 // byte 1, bit 1

Additional Documents

Programming Guideline

...

View file
nameSCL-cheat-sheet.pdf
height250

Direct Adressing Overview

http://www.multiprojekt.pl/ftp/weintek_hmi/plc_connection_guide/Siemens_S7_1200_S7_1500_absolute_addressing_Ethernet.pdf