DUE TO SPAM, SIGN-UP IS DISABLED. Goto Selfserve wiki signup and request an account.
DUE TO SPAM, SIGN-UP IS DISABLED. Goto Selfserve wiki signup and request an account.
...
Introduce new attributes to label Ignite nodes related to different DCs, develop components necessary for operations in MultiDC environment (TopologyValidator, SegmentationResolver with suitable segmentation policy, tooling for managing stretched cluster).
...
At the same time any improvements to TcpDiscoverySpi should not affect single-DC installations (no additional complexity of configuration or performance penalty is introduced).
...
However proposed improvements may enable more efficient algorithms for detecting and handling split-brain, e.g. fast detecting of a split-brain on the edges of DCs or simpler and more efficient TopologyValidator implementations based on the notion of "Leader/Follower DC". However all these ideas are a matter of discussion and clarification.
Thin client has partition-awareness feature. With this feature client connects to all cluster server nodes and tries to find correct node for key and send request to this node (see IEP-23: Partition Awareness for Thin Clients). To achive this client requests primary node map for cache from server. Non partition-awareness requests (not related to cache requests, or without specified key, which can be mapped to node) distributed randomly to all nodes.
In case of multi DC we can make following improvements to PA mechanism:
It's proposed to change "cache partitions" messages (add information about partition in current DC) and introduce new "data center nodes" messages to achive these improvements. Alternatevely, instead of introducing new message we can reuse CLUSTER_GROUP_GET_NODE_IDS message, but in this case client should know about server attribute name to store DC ID (which is server internal information), and everything can be broken if server will change DC ID storage place.
The new operation for "data center nodes" request is required:
| Name | Code |
|---|---|
| OP_CLUSTER_GET_DC_NODES | 5103 |
| Request | |
|---|---|
| String | Data center ID |
| Response | |
|---|---|
| int | Nodes count |
| (UUID) * count | Nodes IDs |
| Request | |
|---|---|
| bool | Custom mapping |
| String | Data center ID - new field |
| int | Caches count |
| (int) * count | Cache IDs |
| Response | |
|---|---|
| long | Major topology version |
| int | Minor topology version |
| int | Partition mappings count |
| (Caches configuration and partition mapping) * count | Caches configuration and partition mappings |
| Caches configuration and partition mapping | |
|---|---|
| bool | Applicable. Flag that shows, whether standard affinity is used for caches. |
| int | Count of caches |
| (Cache ID + key configuration) * count | Cache IDS and cache key configurations |
| Partition mapping | Primary partition mapping (if Applicable is true) |
| Partition mapping | Current DC partition mapping (if Applicable is true) - new field |
| Partition mapping | |
|---|---|
| int | Nodes count |
| (Node ipartitions) * count | Node partitions information |
| Node partitions | |
|---|---|
| UUID | Node ID |
| int | Partitions count |
| (int) * count | Partitions |
Current approach to this IEP introduces components' mostly internal logic modifications, no public API changes or breaking binary compatibility are needed. Protocols stay the same as well with some internal tweaks and possibly some refactoring.
...