[This FLIP proposal is a joint work between Yunfeng Zhou  and Dong Lin ]

Motivation

There are use-cases where job's results need to be emitted only at a minute level latency instead of milli-second level latency. For instance, a user might want to process an unbounded stream of page-view events from Kafka and compute the most-viewed page and its page-view count once every 2 minutes.

Currently, in order to address the above use-case, the Flink job should be run in stream mode and emit one record (i.e. the page-id with its page-view count) for each incoming record. If there are 100 page-view events in 2 minutes, the Flink job will emit 100 records. However, given that the user only needs the result once every 2 minutes, it is unnecessary and wasteful to emit these 100 records. Instead, the job only needs to emit 1 record instead of 100 records, which can significantly reduce network bandwidth usage and reduce the load for the downstream operator/storage.

In order to improve performance and reduce resource usage of Flink jobs, we propose to support user-configurable flush interval, which can be used to adjust the interval of emitting intermediate results for operators with idempotent semantics (e.g. aggregation for keyed inputs). This config effectively allows users to tradeoff between data freshness of the job results and the cost of achieving this data freshness.

Public API

1. Add job-level configuration execution.max-flush-interval

  • Name: execution.max-flush-interval

  • Type: Duration

  • Default value: null

  • Description: 

  • If this configuration is not null, operators with idempotent semantics will emit output records (for keys whose values have been updated) only periodically (up to the specified flush interval) instead of emitting one output record for each input. This config allows operators to reduce the output bandwidth usage with increased throughput, at the cost of increased latency and state size.


2. Add OperatorAttributesBuilder and OperatorAttributes for operator developers to specify operator attributes that can be used for performance optimization, and add the property isOutputIdempotent to OperatorAttribute and the Function interface to indicate whether the operator's output has idempotent semantics.

package org.apache.flink.streaming.api.operators;
 
/** The builder class for {@link OperatorAttributes}. */
@PublicEvolving
public class OperatorAttributesBuilder {
    private boolean isOutputIdempotent = false;
 
  	/** @see OperatorAttributes#isOutputIdempotent */
    public OperatorAttributesBuilder setOutputIdempotent(boolean isOutputIdempotent) {...}

    public OperatorAttributes build() {...}
}
package org.apache.flink.streaming.api.operators;
 
/**
 * OperatorAttributes element provides information about the operator that can be
 * used for performance optimization.
 */
@PublicEvolving
public class OperatorAttributes {
    /**
     * Whether this operator is idempotent. An operator is idempotent if one of the following 
     * conditions are met:
     *
     * <ul>
     *   <li> Its output records are keyed. And when there are multiple output records for the same 
     *     key, the job result is correct if this operator only emits the last record of these records.
     *   <li> Its output records are not keyed. And when there are multiple output records, the job
     *     result is correct of this operator only emit the last record of these records.
     * </ul>
     */
    public boolean isOutputIdempotent() {...}
}
public interface Function extends java.io.Serializable {     
 
    /**
     * Whether this operator is idempotent. An operator is idempotent if one of the following 
     * conditions are met:
     *
     * <ul>
     *   <li> Its output records are keyed. And when there are multiple output records for the same 
     *     key, the job result is correct if this operator only emits the last record of these records.
     *   <li> Its output records are not keyed. And when there are multiple output records, the job
     *     result is correct of this operator only emit the last record of these records.
     * </ul>
     */      
    default public boolean isOutputIdempotent() {
      return false;
    }
}


3. Add the getOperatorAttributes() API to the StreamOperator and StreamOperatorFactory interfaces.

@PublicEvolving
public interface StreamOperator<OUT> extends CheckpointListener, KeyContext, Serializable {
    ...
 
    default OperatorAttributes getOperatorAttributes() {
        return new OperatorAttributesBuilder().build();
    }
}
@PublicEvolving
public interface StreamOperatorFactory<OUT> extends Serializable {
    ...
 
    @Experimental
    default OperatorAttributes getOperatorAttributes() {
        return new OperatorAttributesBuilder().build();
    }
}

Proposed Changes

We propose to add a subclass of the Output interface as follows. When operators output results through this class, this class will buffer the latest results in the state backend until flush() is invoked. A similar subclass of Output will also be introduced in Table/SQL API, which also supports emitting the latest StreamRecord while providing additional support to the Insert/Delete/Update semantics.

/**
 * An {@link Output} that buffers the latest output results from an operator in the state backend.
 *
 * <ul>
 *   <li>If the output result is a StreamRecord, the latest record (of each key, if the operator is
 *       applied on keyed stream, same as below) would be buffered. This means if there has existed
 *       a record (with the same key) in buffer, the record will be overridden by the newly arrived
 *       record.
 *   <li>If the output result is a Watermark, it would be directly emitted if the buffer is still
 *       empty. Otherwise, it would be buffered until flush. Only the latest watermark would be
 *       buffered.
 *   <li>If the output result is a WatermarkStatus, it would be directly emitted if the buffer is
 *       still empty. Otherwise, it would be buffered until flush. Only the latest watermark status
 *       would be buffered.
 *   <li>If the output result is a LatencyMarker, it would be directly emitted if the buffer is
 *       still empty. Otherwise, it would be buffered until flush. All latency marker would be
 *       buffered.
 * </ul>
 *
 * <p>When {@link #flush()} is invoked, all StreamElements in the buffer would be emitted to the
 * actual output, and the buffer would be cleared. If there is watermark or stream records
 * contains timestamp, the buffered elements would be emitted in the following order.
 *
 * <ul>
 *   <li>All stream records whose timestamp is smaller than or equal to the watermark.
 *   <li>The watermark status and watermark, in the order they were buffered.
 *   <li>All stream records whose timestamp is larger than the watermark.
 *   <li>All latency markers.
 * </ul>
 */
@Internal
public class BufferOutput<T> implements Output<StreamRecord<T>> {
    private final Output<StreamRecord<T>> output;

    /** @param output The actual output to flush buffered records to. */
    public BufferOutput(
      ...
      Output<StreamRecord<T>> output
    ) {
        this.output = output;
    }

    @Override
    public void collect(StreamRecord<T> record) {...}

    @Override
    public void close() {...}

    @Override
    public void emitWatermark(Watermark mark) {...}

    @Override
    public void emitWatermarkStatus(WatermarkStatus watermarkStatus) {...}

    @Override
    public <X> void collect(OutputTag<X> outputTag, StreamRecord<X> record) {...}

    @Override
    public void emitLatencyMarker(LatencyMarker latencyMarker) {...}

    public void flush() {
      for (...) {
          output.collect(...)
      }
    }
}

If all of the following conditions are met, OperatorChain would decorate the original mainOutput variable with BufferedOutput before using it to create and setup the operator.

  • execution.max-flush-interval is not null.

  • The operator reports isOutputIdempotent = true


If buffering is enabled according to the requirements above, StreamTask would order the OperatorChain to flush all BufferOutput when any of the following conditions is met during runtime.

  • All input channels are empty and there have been records given to the operator since the last flush.

  • execution.max-flush-interval has passed since the last flush.


Analysis

Performance benefits and overheads brought by this FLIP

If the optimizations proposed in this FLIP is enabled on an operator, its downstream operators would be able to reduce the computation, storage and network resources needed to process the intermediate output results generated by the operator. Suppose the operator used to generate N output records for each key between a max-flush-interval on average, the downstream operators now would only need 1/N of the original resources to handle the incoming data stream, or increase its throughput by N times with the same resource set.

On the other hand, this operator would increate the end-to-end latency of the Flink job, as the latest records would only be output when flush() is triggered. In the worst case where the latest record of a key is buffered right after a flush, the latency of the record would increase by max-flush-interval. Besides, each buffering operation would bring a read & write state access.

Built-in operators and functions that would be affected by this FLIP

With regard to the scenarios in which the optimizations proposed in this FLIP can come to effect, the group-reduce function seems to be the only one among Flink's built-in functions that can utilize these optimizations so far. This would be achieved by having the following operator/function report isOutputIdempotent=true.

  • StreamGroupedReduceOperator

  • GroupAggFunction

After this is applied, the following public API would be able to utilize these optimizations when they are applied on non-windowed stream.

  • DataStream API

    • KeyedStream#reduce

    • KeyedStream#sum

    • KeyedStream#min

    • KeyedStream#max

    • KeyedStream#minBy

    • KeyedStream#maxBy

  • Table API (similar for SQL)

    • BaseExpressions#distinct

    • BaseExpressions#sum

    • BaseExpressions#sum0

    • BaseExpressions#min

    • BaseExpressions#max

    • BaseExpressions#count

    • BaseExpressions#avg

    • BaseExpressions#firstValue

    • BaseExpressions#lastValue

    • BaseExpressions#listAgg

    • BaseExpressions#stddevPop

    • BaseExpressions#stddevSamp

    • BaseExpressions#varPop

    • BaseExpressions#varSamp

    • BaseExpressions#collect


Compatibility, Deprecation, and Migration Plan

The design proposed in this FLIP is backward compatible.

No deprecation or migration plan is needed.

Future Work

1) Add extra mechanism to upper-bound the increase to end-to-end latency.

When a Flink job contains multiple operators in series and more than one of them configure isOutputIdempotent=true, the end-to-end latency brought by each operator might be accumulated and the overall latency overhead could be max-flush-interval * num-operators. This problem is now alleviated by triggering flush when input channels are empty, as described in "Proposed Changes" section.

If the resulting increase to the end-to-end latency is typically much higher than max-flush-interval, we can introduce a control flow message that travels through the job graph in topological order and triggers flush on each StreamTask, and resolve the accumulation of the buffering latency with this message.


2) Deprecate table.exec.mini-batch.* configurations after both FLIP-325 and FLIP-365 has been implemented.

table.exec.mini-batch brings two optimizations: reduced state backend access and reduced number of output records. The design proposed in this FLIP and FLIP-325 can cover these optimizations with the following additional advantages:

  • Less heap memory usage. The operator only needs to store the aggregated value and one output record for each unique key, rather than the full list of the original elements.

  • Better cache hit rate. Since hot key does not have to be evicted from the cache periodically (due to mini-batch processing).

  • No need to increase time of the synchronous checkpoint stage.

  • Applicable to operators in DataStream API as well, instead of only Table/SQL API.





  • No labels