- CDC utility will be started and automatically restarted in the case of failure by the OS or some external tools to provide stable change event processing.
- CDC feature may be used for the deployment that has WAL only.
- At the start of the CDC first consumed event will be the first event available in the WAL archive.
- The lag between the record change and CDC consumer notification will depend on segment archiving timeout and requires additional configuration from the user.
- CDC failover depends on the WAL archive segment count. If the CDC application will be down a relatively long time it possible that Ignite deletes certain archive segments,
therefore consumer can't continue to receive changed records and must restart from the existing segments.
Discussion Links
// Links to discussions on the devlist, if applicable.http://apache-ignite-developers.2346864.n4.nabble.com/DISCUSSION-IEP-59-CDC-Capture-Data-Change-tc49677.html
Reference Links
https://dev.mysql.com/doc/refman/8.0/en/mysqlbinlog.html
...