- Second batch of tests:
- In these tests, Fixed heartbeat and Bertier's strategies did not present any false suspicion. With the given alpha, Chen's presented 13/200 false suspicions, and the Phi-accrual, with the windowminsize parameter equals to 0, have made false suspicion on all the clients. Below, we show the average detection time of all methods but the Phi-accrual:
http://www2.lsd.ufcg.edu.br/~abmar/zk/fd-comparison.png
- The Phi-accrual method must be evaluated again with a better windowminsize parameter in a scenario with a greater duration, so the warm-up period is not considered.
- In these tests, Fixed heartbeat and Bertier's strategies did not present any false suspicion. With the given alpha, Chen's presented 13/200 false suspicions, and the Phi-accrual, with the windowminsize parameter equals to 0, have made false suspicion on all the clients. Below, we show the average detection time of all methods but the Phi-accrual:
...