Apache Ignite should have some general approach to handle critical failures.
The following failures should be treated as critical:
OutOfMemoryError
);User should have an ability to define node behavior in case of this failures.
System critical error - error which leads to the system's inoperability.
The following system critical errors should be handled with proposed approach:
IOException
's threw by read/write operations on file system. The following subsystems should be considered as critical:IgniteOutOfMemoryException
OutOfMemoryError
(we should have some memory reserved for this case at node startup to increase chances to handle OOM).The following system workers are critical and ignite node will be inoperative in case of termination one of this worker:
disco-event-worker
tcp-disco-sock-reader
tcp-disco-srvr
tcp-disco-msg-worker
tcp-comm-worker
grid-nio-worker-tcp-comm
exchange-worker
sys-stripe
grid-timeout-worker
db-checkpoint-thread
wal-file-archiver
wal-write-worker
ttl-cleanup-worker
nio-acceptor
Important notes:
should be extended with methods:IgniteConfiguration
public IgniteConfiguration setFailureHandler(FailureHandler hnd); public FailureHandler getFailureHandler();
Where:
interface FailureHandler { void onFailure(FailureContext failureCtx); } class FailureContext { FailureType type; Throwable error; } enum FailureType { SEGMENTATION, SYSTEM_WORKER_TERMINATION, CRITICAL_ERROR }
FailureHandler
implementation will be able to handle Ignite critical failures accordingly to strategy provided by user.
The following implementations should be provided out of the box:
NoOpFailureHandler
- Just ignores any failure. It's useful for tests and debugging.RestartProcessFailureHandler -
Specific implementation that could be used only with ignite.(sh|bat). Process must be terminated using Ignition.restart(true)
call.StopNodeFailureHandler
- This implementation will stop Ignite node in case of critical error using Ignition.stop(true)
or Ignition.stop(nodeName, true)
call.StopNodeOrHaltFailureHandler(boolean tryStop, long timeout)
- This implementation will try to stop node if tryStop
value is true
. If node can't be stopped during provided timeout
or tryStop
value is false
then JVM process will be terminated forcibly ( Runtime.halt()
).Default failure handler is StopNodeOrHaltFailureProcessor
where tryStop
value is false
.
It's possible that node won't be stopped correctly in case of FailureAction.STOP_NODE
due to some bugs and it can lead to process hanging. This bugs should be discovered ad fixed in the future.