Bug Reference

https://issues.apache.org/jira/browse/CLOUDSTACK-1963

Branch

master, 4.2.0

Introduction

In today's implementation, VMware DataCenter is invisible to CloudStack. CloudStack recognizes and manages cluster as resource container. There is no restriction on which DC or which vCenter instance the cluster, that is being added to cloudstack zone belongs to. This implies following,

  1. Multiple vCenter instances can exist in same cloudstack zone.
  2. Multiple DCs can exist in same cloudstack zone.
  3. Cannot associate N1kv to cloudstack zone because N1kv operates over single DC but cloudstack zone might have multiple DCs underneath (see above point) and also CloudStack doesn't track DC.
  4. A primary storage of the scope zone is not inherently possible because datastore is an object scoped at DC, if a zone contains more than 1 DC this is not supported.
  5. Live migration of VM across clusters in a zone is not inherently possible if 2 clusters are in different DC's.
  6. Multiple cloudstack deployments in same DC enforced 1:1 mapping of ASA instance with cluster & 1:1 mapping of N1kv VSM instance with cluster.
  7. vDS - zone wide traffic label override is required in case of a zone with multiple DCs. vDS specific namespace issues across DCs in vCenter.

To address these issues, Cloudstack should explicitly manage vSphere DCs. Treat CloudStack zone as capacity-planning and operating unit, in case of deployment with multiple DCs use multiple CloudStack zones configured per DC and share the same network infrastructure, they only need to carefully allocate resources like IPs/VLANs etc. to multiple CloudStack zones to make it happen.

Purpose

This document describes the specifications and design of new data model for cloudstack zone for VMware environment.

References

1 http://www.vmware.com/pdf/vsphere5/r51/vsphere-51-configuration-maximums.pdf
2 http://www.vmware.com/pdf/vsphere5/r50/vsphere-50-configuration-maximums.pdf
3 http://www.vmware.com/pdf/vsphere4/r41/vsp_41_config_max.pdf

Document History

Author

Description

Date

Sateesh Chodapuneedi

Initial Revision

04/09/2013

Glossary

DC - VMware vCenter Data Center.
N1kv - Cisco Nexus 1000v Distributed Virtual Switch
vDS - VMware vNetwork Distributed Virtual Switch.
vSwitch - VMware vNetwork Standard Virtual Switch
dvPortgroup - VMware vNetwork Distributed Virtual Portgroup
Portgroup - VMware vNetwork Standard Virtual Portgroup

Feature Specification

With this feature, Vmware datacenter will be put under management of CloudStack zone.
In previous releases, Vmware datacenter is hidden behind a CloudStack cluster, we need an explicit mapping policy for Vmware datacenter both for zone-wide storage and zone-wide network resources. This makes datastore in a DC to span across clusters scoped by cloudstack zone. Also this means dvSwitch in DC spans across clusters in the zone. VM live migration across clusters in zone can be realized with this model.

1:1 relationship between vSphere DC to CloudStack zone is a natural mapping from resource point of view, whether it's storage (datastore) or network (distributed switches etc.). Within the zone/DC, it's possible to have multiple vSphere clusters (within the same DC). And this will have the implication that CloudStack zone size (how many hosts within a zone) will be limited to what vSphere allows. See 1, 2 & 3 in References section.

Test Guidelines

  1. All VMware test cases need to be covered, as new mapping of DC to CloudStack zone is a change in critical path of VMware hypervisor plugin.

Hypervisor support

  • VMware ESXi 4.1 or later.

Negative usage scenarios

  1. A DC should not be allowed to be part of multiple CloudStack deployments.
  2. In a CloudStack deployment, a DC should be associated with only one CloudStack zone.

Supportability characteristics

Logging

VMware hypervisor plugin logs all the successful operations to INFO, all exceptions/failures to ERROR, and all synchronization checks to DEBUG.

Debugging/Monitoring

In addition to looking at the management server logs, administrators can look up the vcenter logs for analysis.

Use cases

It allows the system administrator to configure cloudstack zone per DC to manage all the the resources in DC.

  • All DC wide features would be available across cloudstack zone.
  • Zone wide virtual network orchestration is supported using distributed virtual switch (VMware DVS, Nexus 1000v DVS)
  • Zone wide storage/datastore.

Architecture and Design description

Vmware datacenter will be put under management of CloudStack zone.

In this explicit model, CloudStack will understand the relationship between a Vmware datacenter and resources underneath it, so when resources like a Vmware cluster or dvSwitch that is added to CloudStack, the underlying Vmware resource relationship between these objects will become constraint information for CloudStack to use.
For example, a Vmware cluster can't be added to a CloudStack zone if it's Vmware DC is not under the CloudStack zone, also an ASA instance cannot be added to a Vmware cluster that its Vmware DC is not in the zone.

The model itself will not limit how many Vmware clusters that a N1kv VSM instance or ASA or vDS will manage, as long as N1kv or ASA or vDS and its managed cluster are within the same Vmware DC.

  • CloudStack should manage following DC level resources in scope of zone.
  1. Manage Clusters
  2. Manage Datastores for zone wide storage
  3. Manage distributed virtual switches for zone wide virtual networks.
    1. Nexus 1000v DVS
    2. VMware DVS
  • Single DC will NOT be allowed to be managed by multiple cloudstack deployments. Add custom property to DC to flag if DC is being managed by cloudstack. Flag needs to be cleared upon 'unmanaging'/'removing' the last cluster in that zone.

Database modifications

  1. cloud.data_center_details table will be used to populate a key value pair (key: vmwaredc) to store DC associated with zone.

Web Services APIs

  1. AddCluster will be modified
    1. Make vCenter credentials optional based on vmwaredc key's presence in data_center_details.

UI Flow

  • Changes required in UI for live migrating a volume from one storage pool to another.
    1. Add Cluster form in zone wizard
    2. Add Cluster wizard
    3. Add NexusVSM instance to zone
    4. Add ASA instance to zone

Open Issues

  1. Choosing to NOT allowing single DC to be managed by multiple cloudstack deployments. Name space collision issues within DC will be resolved by this.

Impact on other areas/features

  1. Impact of this feature on zone wide primary storage support - vmware.
  2. Impact of this feature on storage live migration - vmware.
  3. Cisco Nexus 1000v support needs changes. 1 cluster to 1 Nexus mapping to be removed. Allow Nexus 1000v VSM instance to be associated/dis-associated with zone.
  4. Impact of this feature on ASA feature needs check.
  5. Impact of this feature on refactoring in Vmsync.

Upgrade

  1. Migration support
    1. Existing CloudStack Deployments - Existing cloudstack deployments with multiple DC's in a zone
      1. Decide a DC as the final DC that contains all clusters.
      2. Move all clusters to the chosen DC.
      3. For each cluster create cluster with same name in target DC.
      4. Edit the field 'cloud'.'cluster'.'name' in database to reflect new DC name in cluster name.
      5. Edit the field 'cloud'.'cluster_details'.'url' in database to reflect new DC name in cluster name.
      6. Cold migrate each of the instance to this new cluster in chosen DC.
    2. Fresh CloudStack Deployments - Existing VMware deployments with clusters to be managed by cloudstack spread in multiple DC's
      1. Move all clusters meant for single zone into 1 DC
      2. For each cluster create cluster with same name in target DC.
      3. Put each host, in that cluster, in maintenance mode
      4. Remove each host in maintenance mode from the cluster
      5. Add each host to new cluster in target DC
      6. Get the host out of maintenance mode